Model 40922 - DOSIMETER ALPHAplus
ALPHAplus Dosimeter for constancy testing of X-ray exposure equipment as well as for mammography. With LCD, serial interface and plug-in for different detectors. Display of: dose, dose rate and exposure time.
Model 40916 - ABSORPTION FILTER
Fits the ALPHAplus Dosimeter for the constancy test of all analog X-ray equipment (direct radiography, fluoroscopic techniques). Not for digital or mammography X-ray equipment! The sensor is located above the patient-equivalent-filter (25mm Al) under the insertion plate. Energy range: 50kV – 155kV Effective dose range: 0,1mGy/s – 500mGy/s
Model 40915 - FINGER DETECTOR
Fits the ALPHAplus Dosimeter for the constancy test of digital and analog X-ray-equipment (direct radiography and fluoroscopy; not for dental or mammography systems). Because of its shape the sensor is suitable for insertion into the patient-equivalent-filter for use with near-the-tube measurements as well as an external sensor. Energy range: 50kV – 155kV Effective dose range: 0,1mGy/s – 500mGy/s
Model 40923 - MAMMOGRAPHY DETECTOR
Fits the ALPHAplus Dosimeter for the constancy test of all analog or digital mammography X-ray equipment.
– Energy range: 24kV – 40kV
– Effective dose range: 0,1mGy/s – 500mGy/s
Click here to download our complete QA product catalog.
Model 40928 - ALPHAplusA
Click here to download the full product specifations.
Model 40922 - ALPHAplus
Click here to download the full product specifations.
Model 40916 - ABSORPTION FILTER
Fits the ALPHAplus Dosimeter for the constancy test of all analog X-ray equipment (direct radiography, fluoroscopic techniques). Not for digital or mammography X-ray equipment! The sensor is located above the patient-equivalent-filter (25mm Al) under the insertion plate. Energy range: 50kV – 155kV Effective dose range: 0,1mGy/s – 500mGy/s
Model 40915 – FINGER DETECTOR
Fits the ALPHAplus Dosimeter for the constancy test of digital and analog X-ray-equipment (direct radiography and fluoroscopy; not for dental or mammography systems). Because of its shape the sensor is suitable for insertion into the patient-equivalent-filter for use with near-the-tube measurements as well as an external sensor. Energy range: 50kV – 155kV Effective dose range: 0,1mGy/s – 500mGy/s
Model 40923 –MAMMOGRAPHY DETECTOR
Fits the ALPHAplus Dosimeter for the constancy test of all analog or digital mammography X-ray equipment.
– Energy range: 24kV – 40kV
– Effective dose range: 0,1mGy/s – 500mGy/s
Click here to download our complete QA product catal